- Manuals
- Brands
- GHP Group Manuals
- Heater
- Dyna-Glo TT360PL-1
- User's manual and operating instructions
Propane tank top construction heater
Hide thumbs
-
- Contents Table of Contents
- Troubleshooting
- Bookmarks
Advertisem*nt
Quick Links
Download this manual
This Owner's Manual is provided and hosted by Appliance Factory Parts.
DYNA-GLO TT360PL-1
Owner's Manual
Shop genuine replacement parts for DYNA-GLO
TT360PL-1
Find Your DYNA-GLO HVAC Parts - Select From 146 Models
-------- Manual continues below --------
Table ofContents
Advertisem*nt
Related Manuals for GHP Group Dyna-Glo TT360PL-1
-
Gas Heater GHP Group TT360L User's Manual And Operating Instructions
Propane tank top construction heater (20 pages)
-
Gas Heater GHP Group TT3-40C User's Manual And Operating Instructions
Propane tank top construction heater (20 pages)
-
Heater GHP Group TT15CL User's Manual And Operating Instructions
Propane tank top construction heater (19 pages)
-
Heater GHP Group TT15CPDG User's Manual And Operating Instructions
Propane tank top construction heater (20 pages)
-
Heater GHP Group Dyna-Glo RMC-FA40 User Manual
Propane construction heater (21 pages)
-
Heater GHP Group Dyna-Glo WK95C8 Owner's Manual
Portable kerosene-heater (54 pages)
-
Heater GHP Group Dyna-Glo Delux SF70DGD User's Manual And Operating Instructions
Indoor/outdoor products kerosene portable forced air heaters (54 pages)
-
Heater GHP Group Dyna-Glo ELUX KFA650DGD User Manual
Kerosene portable forced air heaters (24 pages)
-
Heater GHP Group FA40 BTU Series User's Manual And Operating Instructions
Propane construction heater (20 pages)
-
Electric garage heater 10,000w / 240v / 34,120 btu (48 pages)
-
Heater GHP Group M75DGD User's Manual And Operating Instructions
Kerosene portable forced air heaters (90 pages)
-
Heater GHP Group RMC-KFA650TDGD User's Manual And Operating Instructions
Kerosene portable forced air heaters (25 pages)
-
Heater GHP Group RMC-KFA400TDGD User's Manual And Operating Instructions
Ndoor/outdoor products kerosene portable forced air heaters (25 pages)
Summary of Contents for GHP Group Dyna-Glo TT360PL-1
- Page 1 This Owner's Manual is provided and hosted by Appliance Factory Parts. DYNA-GLO TT360PL-1 Owner's Manual Shop genuine replacement parts for DYNA-GLO TT360PL-1 Find Your DYNA-GLO HVAC Parts - Select From 146 Models -------- Manual continues below --------...
- Page 2 TT360PDGP TT360DGD TT360PDGD ANS Z83.7-2011 CSA 2.14-2011 Adequate ventilation must be provided. GHP Group, Inc. 6440 W Howard St Niles, IL 60714-3302 GENERAL HAZARD WARNING FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PROVIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY AND PROPERTY LOSS, OR DAMAGE FROM THE HAZARDS OF FIRE, EXPLOSION, BURN.
-
Page 4: Table Of Contents
TABLE OF CONTENTS General Safety Information ................3 - 4 Specifications ......................Product Features ..................... Heater Assembly ....................... Wiring Diagram ......................Propane Safety ......................Refilling The Propane Gas Tank ................Connecting Heater to Gas Supply ................8 - 9 Checking For Leaks ....................10 Lighting &... -
Page 5: General Safety Information
PROPANE TANK TOP HEATER PROPANE TANK TOP CONSTRUCTION HEATERS The heater is designed and approved for use as a construction heater under ANSI Z83.7, CSA 2.14. CHECK WITH YOUR LOCAL It is hard to anticipate every use which may be made of this heater. FIRE SAFETY AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS. -
Page 6: Product Features
PROPANE TANK TOP HEATER GENERAL SAFETY INSTRUCTIONS Accidents are always tragic especially because so many of them could have been prevented with a little care and judgment. There are some basic good practices, we hope you will follow for safe use of your heater. IMPORTANT SAFETY INFORMATION •... -
Page 7: Heater Assembly
PROPANE TANK TOP HEATER TT360 SERIES HEATER ASSEMBLY Tools Required: Estimated Assembly Time: Contents: Phillips head screwdriver 5 minutes Tank Top Heater (1) Tank Collar Bracket (1) M4x8 Machine Screws (2) DUAL BURNER MODEL The tank collar bracket must be assembled before the heaters can be attached to the propane tank. 1. -
Page 8: Wiring Diagram
PROPANE TANK TOP HEATER WIRING DIAGRAM ELECTRODE black earth yellow THERMOCOUPLE yellow M,P,U SAFETY VALVE NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! -
Page 9: Propane Safety
PROPANE TANK TOP HEATER PROPANE SUPPLY This heater requires a 20 lb propane cylinder for operation. (Not included). The propane (LP) gas tank must also be equipped with the following: • A collar to protect the propane gas valve. • A shutoff valve terminating a Propane gas cylinder valve outlet as specified in the American National Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections. -
Page 10: Connecting Heater To Gas Supply
PROPANE TANK TOP HEATER CONNECTING HEATER TO PROPANE TANK Read and understand all safety information before connecting heater to propane tank. 1. Place heater onto tank with tank collar bracket over tank collar (Fig. 2). Mounting bolt knob should be positioned to the outside of tank collar and be positioned as closely as possible directly opposite to the cylinder valve outlet. - Page 11 PROPANE TANK TOP HEATER CONNECTING HEATER TO PROPANE TANK FIGURE 2 NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING!
-
Page 12: Checking For Leaks
PROPANE TANK TOP HEATER CHECKING FOR LEAKS Check all gas connections with a 50/50 soap and water solution to be sure they are tight and leak proof. The formation of bubbles indicate a gas leak. Correct all leaks before using the heater. •... - Page 13 PROPANE TANK TOP HEATER LIGHTING INSTRUCTIONS WHEN USING MATCH (CONTINUED) FIGURE 3 1. STOP! Read all safety information first. 2. Turn heater regulator knob counterclockwise to (OFF) [ ] position. 3. Slowly Open Cylinder valve by turning counterclockwise 4. Wait five(5) minutes to clear out any gas. Then smell for gas, including near the floor.
- Page 14 PROPANE TANK TOP HEATER TURNING OFF THE HEATER 1. Tightly close propane tank valve by turning fully clockwise 2. Turn the heater regulator knob to the (OFF) [ ] position. Wait at least 30 minutes for the heater to cool before handling heater.
- Page 15 PROPANE TANK TOP HEATER LIGHTING INSTRUCTIONS FOR PIEZO IGNITION MODELS (CONTINUED) 1. Stop! Read all safety information first. 2. Turn heater regulator knob counterclockwise to (OFF) [ ] position. WARNING: Stand to the side of unit while lighting. Do not stand or have any part of your body over or near the heater while lighting.
-
Page 16: Storage Of Heater
PROPANE TANK TOP HEATER LIGHTING IN WINDY AREAS When using this heater indoors where there is wind, it will be necessary to use a match or long stem butane lighter to ignite the burner. It may be difficult to keep the match lit long enough under windy conditions. Follow the “Lighting instructions when Using a Match”... -
Page 17: Troubleshooting
PROPANE TANK TOP HEATER TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION 1. Unit will not light. 1. Valve on propane cylinder not open. 1. Open cylinder valve by turning counterclockwise. 2. Propane cylinder empty 2. Have cylinder refilled. 3. Regulator not in "Low" position 3. Turn regulator to "Low" position. 4. Excess flow device triggered. 4. Close cylider valve, wait 5 minutes and reopen slowly. 5. Defective Regulator. 5. Replace Regulator assembly. 2. Burner will not stay lit when 1. Tilt switch open 1. Correct alignment of unit to ensure it is vertical. gas valve plunger released. 2. Wiring of thermocouple 2. Check wiring connections are properly engaged. 3. -
Page 18: Exploded Parts Drawing
PROPANE TANK TOP HEATER REPLACEMENT PARTS ILLUSTRATION NEVER LEAVE THE HEATER UNATTENDED WHILE BURNING! - Page 19 THIS PAGE INTENTIONALLY LEFT BLANK.
-
Page 20: Warranty
This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers as directed by GHP Group, Inc., within one (1) year of retail purchase. - Page 21 6 0 0 5 3 - 3 2 0 7 Tel: ( 847 ) 324 - 5900 Fax: ( 847 ) 324 - 5901 SAVE THIS CARD! Toll Free (877) GHP Group ( 8 7 7 ) 4 4 7 - 4 7 6 8 www.ghpgroupinc.com Place...